Shanghai Toppower-Asia Co., Ltd. · 鼎胜嘉威
Transformers, switchgear and battery storage, configured to your grid
Oil-immersed and dry-type transformers, compact substations, MV and LV switchgear and LiFePO4 storage from Shanghai, built to your standard and site conditions and shipped worldwide.
- Product lines
- 9
- Standard configurations
- 140
- Voltage range
- 0.4–230kV
- Storage per system
- 10MWh max
- Built to
- IEC, IEEE, GB, GOST
The range
From a 15 kVA pole transformer to a 420 MVA grid transformer

01 / 09 · Pole-Mounted Transformers
Pole-mounted
15–333 kVA
Oil-immersed single-phase units for overhead lines, rural electrification and residential feeders, conventional or completely self-protected.
- Configurations
- 16
- Voltage class
- 7.2–14.4 kV
- Standards
- IEC, ANSI/IEEE, GB
- Phases
- Single-phase
Popular configurations

02 / 09 · Pad-Mounted Transformers
Pad-mounted
15–1,500 kVA
Tamper-resistant ground-level units for underground residential and commercial networks and solar collection, loop or radial feed, dead-front.
- Configurations
- 5
- Voltage class
- 13.8–34.5 kV
- Standards
- IEC, GB
- Phases
- Three- or single-phase
Popular configurations

03 / 09 · Dry-Type Transformers
Cast-resin dry-type
30–5,000 kVA
Epoxy cast-resin transformers for hospitals, data centres, high-rise buildings and plants where fire safety rules out oil.
- Configurations
- 16
- Voltage class
- 0.4–35 kV
- Standards
- IEC, GB
- Phases
- Three-phase
Popular configurations

04 / 09 · Oil-Immersed Transformers
Oil-immersed
15 kVA–31.5 MVA
Sealed or conservator-type distribution and power transformers for outdoor networks and industrial supply, ONAN or ONAF.
- Configurations
- 19
- Voltage class
- 6–35 kV
- Standards
- IEC, GB, ANSI/IEEE
- Phases
- Three-phase
Popular configurations

05 / 09 · Transformer Substations
Box substation
up to 5,000 kVA
MV switching, transformer and LV board factory-built into one European, American or container enclosure.
- Configurations
- 23
- Voltage class
- 0.4–36 kV
- Standards
- IEC, GB
- Phases
- Three-phase
Popular configurations

06 / 09 · HV & LV Switchgear
MV switchgear
6.3–35 kV
Ring main units, KYN28 metal-clad panels, SF6 or solid-insulated cabinets and GCS draw-out LV boards.
- Configurations
- 15
- Voltage class
- 0.4–35 kV
- Standards
- IEC
- Phases
- Three-phase
Popular configurations

07 / 09 · Liquid-Cooled Storage Cabinets
Liquid-cooled cabinet
40–500 kWh
Liquid-cooled LFP cabinets for demand-charge reduction, solar self-consumption and diesel-hybrid sites.
- Configurations
- 14
- Voltage class
- Low voltage DC/AC
- Standards
- IEC
- Phases
- Three-phase AC
Popular configurations

08 / 09 · Battery Energy Storage Systems
BESS container
0.5–10 MWh
Containerised LFP storage with BMS, PCS and EMS for solar time-shift, peak shaving and grid services.
- Configurations
- 16
- Voltage class
- Low voltage DC/AC
- Standards
- IEC
- Phases
- Three-phase AC
Popular configurations

09 / 09 · Power Transformers
Power transformer
up to 420 MVA
Two- and three-winding transformers with on-load tap changers for grid and generation substations, 66–230 kV class.
- Configurations
- 16
- Voltage class
- 10–230 kV
- Standards
- IEC, GB
- Phases
- Three-phase
Popular configurations
Nine product lines, from medium voltage to the busbar
Every line is configured to the buyer's grid data. Hover a line to preview it, or filter the full catalogue by rating, voltage and application.
Transformer Substations
Box-type, European-, American- and prefabricated substations from 6.3 kV to 36 kV and up to 5,000 kVA, built around one transformer, MV switching and an LV board in a single enclosure.
23Oil-Immersed Transformers
Hermetically sealed and conservator-type distribution and power transformers, 15 kVA to 31,500 kVA at 6–35 kV, with copper or aluminium windings and ONAN/ONAF cooling.
19Dry-Type Transformers
Cast-resin transformers from 30 kVA to 5,000 kVA at 6.3–35 kV, Class F/H insulation, for indoor sites where oil is not acceptable.
16Power Transformers
Oil-immersed power transformers from 1 MVA to 50 MVA and above, 66–230 kV class, with on-load tap changers for grid and generation substations.
16Pad-Mounted Transformers
Single- and three-phase pad-mounted transformers, 15–1,500 kVA, loop or radial feed, dead-front, built to ANSI/IEEE C57.12.
5Pole-Mounted Transformers
Single-phase and three-phase overhead-line transformers, 15–333 kVA at 7.2–34.5 kV, for rural electrification and residential feeders.
16HV & LV Switchgear
Low-voltage GCS/MNS boards, KYN28 metal-clad switchgear, ring main units and SF6 or solid-insulated cabinets from 400 V to 35 kV.
15Battery Energy Storage Systems
Containerised LiFePO4 battery energy storage from 500 kWh to 10 MWh, with BMS, PCS and EMS integrated for solar, grid and C&I projects.
16Liquid-Cooled Storage Cabinets
Liquid-cooled LFP cabinets and containers from 40 kWh to 372 kWh per unit for commercial, industrial and microgrid storage.
14
From grid to load
Where each product sits in your network
Follow the power path from the grid connection to the load. Select any stage to see what we supply there, its range and typical configurations.
Stage 1 of 6
Grid connection
66–230 kV
Transmission or sub-transmission supply from the utility, or the export point of a solar, wind or storage plant.
What to send us
- Single-line diagram and connection voltage
- Fault level and earthing arrangement
- Load list or maximum demand
- Site altitude, ambient and destination
Stage 2 of 6
Power transformer
1–420 MVA
Steps transmission voltage down to medium voltage at the grid substation, or steps generation up for export. Two or three windings, ONAN/ONAF cooling and on-load tap changers.
Typical configurations
110/115kV OLTC Power Transformer 20, 25 and 50 MVA with 11kV or 23kV Secondary20–50 MVA · 11–115 kV
110kV to 35kV Step-Down Power Transformer 15, 20 and 25 MVA, ONAN/ONAF Cooled15–25 MVA · 110 kV / 35 kV
40 MVA Copper-Wound PV Substation Transformer, 66kV to 15kV or 20kV, Oil-Immersed40 MVA · 15–66 kV
Stage 3 of 6
MV switchgear
6.3–35 kV
Switches and protects the medium-voltage feeders: KYN28 metal-clad panels with vacuum breakers, ring main units for looped cable networks, SF6 or solid-insulated cabinets.
Typical configurations
Stage 4 of 6
Distribution transformer
15 kVA–31.5 MVA
Brings medium voltage down to 400 V, 415 V or 480 V at the point of use. Oil-immersed for outdoor sites, cast-resin dry-type indoors, pad- or pole-mounted on distribution networks.
Typical configurations
Stage 5 of 6
LV switchgear
0.4–1 kV
GCS and MNS draw-out switchboards and motor control centres distribute power to feeders, motors and building services.
Stage 6 of 6
Loads
Plants, buildings, EV
Factories, commercial buildings, data centres, mines, EV charging and the auxiliary supply of renewable plants.
What to send us
- Single-line diagram and connection voltage
- Fault level and earthing arrangement
- Load list or maximum demand
- Site altitude, ambient and destination
Branch
Battery storage
0.5–10 MWh
Containerised LiFePO4 storage on the MV bus with a step-up skid: solar time-shift, peak shaving, frequency response and backup for the whole site.
Branch
C&I storage cabinet
40–500 kWh
Liquid-cooled LFP cabinets on the LV side, behind the meter: demand-charge reduction, solar self-consumption and diesel-hybrid supply.
Packaged option
Box substation
up to 5,000 kVA
MV switching, the distribution transformer and the LV board factory-built into one European, American or container enclosure, so site work shrinks to a foundation and cable entries.
How every order runs
Five documented steps from enquiry to after-sales support, the same whether you order one pole transformer or a substation package.

- 01
Specification review
Engineers check your enquiry against the network: voltage and frequency, fault level, earthing, ambient, altitude and the governing standard.
- 02
Technical proposal
Ratings, losses, impedance, dimensions, weights and the applicable routine and type tests, with drawings when the project needs them.
- 03
Production follow-up
After drawing approval we track production milestones and report progress, so delivery dates are managed rather than guessed.
- 04
Inspection and testing
Routine tests before shipment, with reports. Customer or third-party witness inspection can be arranged on request.
- 05
Packing and support
Sea- or land-freight packing, shipping documents, manuals, spare parts and remote technical assistance after delivery.
Size a distribution transformer in a minute
Enter your load and site conditions. The calculator applies demand and growth, picks the next standard rating and tells you what to state in the specification for hot or high sites.
Recommended standard rating
1000kVA
- Maximum demand
- 753 kVA
- Design load incl. growth
- 941 kVA
- Loading today / after growth
- 75% / 94%
- Full-load current at LV
- 1443 A
- Site correction to specify
- None
An estimate for early planning. Motor starting, harmonics and diversity between load groups can change the answer; see how to size a distribution transformer.
Request a quote for this ratingApplication examples in 15 countries
Representative configurations for typical projects, every one supplied from Shanghai. Select a country to open its equipment package and quotation checklist.
Kenya50 Hz · Substation
Vietnam50 Hz · Substation22 kV/0.4 kV Compact Prefabricated Substation
Saudi Arabia60 Hz · Transformer33 kV/13.8 kV Solar Step-Up Transformer Bay
Tanzania50 Hz · Transformer11 kV/0.4 kV Pole-Mounted Transformer for Rural Networks
Indonesia50 Hz · Substation20 kV/0.4 kV Containerised Substation for Mining
United Arab Emirates50 Hz · Switchgear11 kV Switchgear Lineup for Commercial Buildings
Brazil60 Hz · Transformer34.5 kV/480 V Pad-Mounted Transformer for Solar Plants
Chile50 Hz · Substation33 kV Prefabricated Step-Up Substation for a Wind Farm
Germany50 Hz · Energy storage2 MWh Liquid-Cooled Containerised Battery Storage
Philippines60 Hz · Energy storage13.8 kV Containerised Substation for an Island Microgrid
South Africa50 Hz · Transformer11 kV/0.4 kV Cast-Resin Dry-Type Transformer for a Mining Plant
Egypt50 Hz · Transformer66 kV/11 kV Oil-Immersed Grid Transformer
Kazakhstan50 Hz · Substation35 kV/10 kV Insulated Prefabricated Substation for Extreme Cold
Australia50 Hz · Energy storage5 MWh Liquid-Cooled Containerised BESS with 22 kV Step-Up
Mexico60 Hz · Substation13.8 kV/480 V Compact Substation for an Automotive Components Factory
Why buyers work with Toppower Asia
One engineering contact from specification to the quay in Shanghai, and after the equipment arrives.
One supplier, nine product lines
Transformers, switchgear, substations and storage under one quotation.
Built to your standard
IEC, ANSI/IEEE, GB or GOST; 50 Hz or 60 Hz.
Engineered, not just quoted
Every enquiry gets a specification review before pricing.
Tested before it ships
Routine test reports supplied with every unit.
Export-ready
Sea-worthy packing and complete shipping documentation.
From the engineering blog
Practical guides for specifying, comparing and buying power equipment.
75 kVA transformer: full-load amps, voltages and uses
75 kVA transformer guide: full-load amps at 120/240 V, 208Y/120 V, 400 V, 480 V and 11 kV, single- vs three-phase options, typical uses and how to specify one.
Frequently asked questions
Short answers to the questions buyers ask most. For anything specific to your project, send us your specification.
What products does Toppower Asia supply?
Oil-immersed, cast-resin dry-type, power, pad-mounted and pole-mounted transformers; box-type and container substations; medium- and low-voltage switchgear and ring main units; and LiFePO4 battery energy storage from 40 kWh cabinets to 10 MWh containers. That is nine product lines and about 140 standard configurations.
Which standards can equipment be built to?
IEC 60076, IEC 62271 and IEC 61439, ANSI/IEEE C57, and national standards such as GB or GOST where a project requires them. Frequency (50 or 60 Hz), voltage ratio, vector group, conductor material, cooling and enclosure protection are matched to the project.
What do you need from me to prepare a quotation?
A single-line diagram or tender specification is ideal. Otherwise send the rated power, primary and secondary voltages, frequency, vector group, quantity, applicable standard, site conditions (altitude, ambient temperature, indoor or outdoor) and the destination port.
Are units tested before shipment?
Yes. Routine tests appropriate to the product are carried out before shipment, and the test reports travel with the equipment. Customer or third-party witness inspection can be arranged on request.
Do you ship worldwide?
Yes. Equipment is packed for sea or land freight and shipped with its test reports and manuals. Common terms are FOB Shanghai, CIF and DAP; tell us your destination port and preferred Incoterms.
Which certificates come with the equipment?
Test reports are supplied with every order. Product certification required by the destination market, such as CE, UL or EAC, is discussed and confirmed for each project before order rather than assumed.
Send your single-line diagram. Get a technical proposal back.
Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.
- kevin@toppower-asia.com
- WhatsApp / WeChat +86 186 1664 1467
- Room A09, Building 2, No. 619 Longchang Road, Yangpu District, Shanghai, China